• OminousOrange@lemmy.ca
    link
    fedilink
    arrow-up
    4
    ·
    edit-2
    11 months ago

    A couple things to add to sonori’s reply, the system efficiency also goes up when you can use higher capacity inverters. Essentially, one grid-scale facility (say, 100 MW) will have far fewer inverters than 100 MW of rooftop systems, meaning less efficiency loss.

    While larger facilities can be optimized for azimuth and sun angle or with tracking, rooftops are often not optimally aligned, leading to a decrease in capacity. Sure, you could add tracking to your residential system, but that’s a significant cost that many homeowners won’t see the benefit of. There might also be obstacles that shade a residential system, which is often addressed when selecting sites for larger systems.

    • jadero@slrpnk.net
      link
      fedilink
      arrow-up
      2
      ·
      11 months ago

      I’m not disagreeing with anything you’ve said, but there is a bit of nuance on optimal angle. I’m also in SK (about 50.7 degrees), and when I was looking at putting up panels, it was cheaper to throw a couple of extra panels up than to modify the install for “optimal fixed angle”.

      Obviously, starting from scratch, you’d be foolish to not include “optimal fixed angle” or maybe even a manually operated dual-angle system that has a “summer position” and a “winter position”. For my install, a dual-angle install would have required the same number of panels as an optimal fixed angle. I would have got a larger margin of overproduction, but not by enough to eliminate a panel.

      A lot of what I see on solar panels is still stuck using the same analyses as when they were less efficient, more sensitive to clouds, and more expensive. It wouldn’t surprise me to learn that even large scale installations would be better served by eliminating the expense and maintenance costs of tracking instead of pushing for maximum performance.

      (Note: we didn’t ever get the install, because we couldn’t get financing, even when SaskPower was still doing full retail buyback.)

      • OminousOrange@lemmy.ca
        link
        fedilink
        arrow-up
        2
        ·
        11 months ago

        Yeah, standard installations will often be cheaper than a customized mounting. I’m at 52.9 and have a rooftop system with two arrays directed SW and SE because of rooflines (sized so the house is net-zero - 39 panels for 14 kW which gets me about 15,000 kWh annually), but I’d definitely go ground mount with a summer/winter position rack if I were to do it again. I work a bit with simplified PV modelling now and am disappointed that I didn’t know more sooner, probably would’ve saved quite a few dollars.

        We also did an early feasibility study for a 10 MW farm and did find that tracking was marginally better, even including maintenance costs, but that does introduce the risk of labour availability and cost fluctuations that isn’t there on fixed mount. Overall, the project wasn’t feasible with the rates SaskPower pays.

        • jadero@slrpnk.net
          link
          fedilink
          arrow-up
          1
          ·
          11 months ago

          Our initial plan based on my research was a ground system, not a roof system. South instead of southwest, fewer trees in the way, easy manual angle adjustment, easier to clear snow.

          That would have saved us at least one panel and made it easier to add or replace panels.

          The “wasted space” would be suitable for storage of various yard tools and equipment or a slightly taller mount might have made a nice shaded patio.

          According to the contractors, the cost would have been substantially higher than a roof because of the difference in engineering costs and the legal requirement for fencing. I’ve since seen enough ground installs to think that the engineering and fencing requirements were not legitimate. I haven’t seen a single fenced installation and the support structures all look enough alike that I suspect the engineering is as close to a rubber stamp as a roof install.

          We’re retired now. Without substantial grants, the window of opportunity has passed. With what I’ve learned in the last few years, I suspect that a ground mount would have actually saved us enough money to fit our line of credit instead of having to go hat in hand to the bank.

          Oh well. Next up is heat pump. A preliminary look at federal funding makes me think that we can manage the capital outlay, leaving our pellet stove for just the coldest days.

          • OminousOrange@lemmy.ca
            link
            fedilink
            arrow-up
            2
            ·
            11 months ago

            There are definitely differences in installation, like piles instead of roof brackets, but I don’t imagine there’d be too big a difference in cost as long as there was local equipment to drill for the piles. And yes, I believe fences are only needed for larger installations.

            Heat pumps are much more efficient than resistive electric heat, but you won’t save utility bills if you already have natural gas heat. Right now, electricity is about 9x more expensive for the same unit of heat compared to NG. I’d otherwise recommend it if you value emissions reductions over costs, though.

            • jadero@slrpnk.net
              link
              fedilink
              arrow-up
              1
              ·
              11 months ago

              Natural gas is not available to us.

              Our residential heat (900 ft² mobile home) is a 20-year old pellet stove with occasional use of a space heater in the opposite end of the building. There is no evidence that it’s on the way out, but it is 20 years old. We use 150-180 40lb bags of pellets to the tune of $1300-$1500 per year, plus the power used by the stove.

              My shop (250 ft²) gets enough heat from occasional use of an external wood-fired rocket stove with heat exchanger for 3-season use. On colder days, I add in the overhead 750/1500 watt electric radiant heater so that I don’t have to wait 3 hours for the shop to come up to temperature, but I try to not use the shop when it’s colder than about -10C.

              My analysis suggests that I can save at least $1000/year on pellets and eliminate the use of space heaters and rocket stove while also making it much easier to heat the shop when I need it. $1000/year (really, 6-7 months) goes a long way to making up the difference between current electrical use and expected electrical use.

              And even if I’ve miscalculated, we can afford to pay a bit more to reduce wood use and resistive heating. One thing I’ve learned is that the best pellet stoves still put out more particulates than I’d like, and the rocket stove is worse. (Although the rocket stove is far better than the a campfire and people go through a lot more wood for their campfire than I use in the rocket stove.)

              • OminousOrange@lemmy.ca
                link
                fedilink
                arrow-up
                2
                ·
                11 months ago

                Ah, then yes, you’d benefit quite a bit from a heat pump. I’d keep the existing systems as backup for those extra cold days, but otherwise it sounds like a great upgrade, and you get the bonus of cooling in the summer.

                • jadero@slrpnk.net
                  link
                  fedilink
                  arrow-up
                  1
                  ·
                  11 months ago

                  Keeping the other systems operational for the coldest days and backup is the plan.

                  We’ve done fine with just a smallish room AC, but our heat tolerance is going down as we age, so having a bit more cooling would be nice.