Currently doing drywall myself and I am using 6x6 cm squared timber around my outside walls.

The problem is they aren’t as stable as the other walls inside the house because of the 6x6 cm squared timbers that are about 30cm distance from each other.

I will screw my plasterboards on the squared timber and only one plasterboard, not two.

I have two pictures of what my construction looks like from far and one from close.

Maybe someone can give me advice before I install the plasterboard onto it.

The only problem I currently see is finding the subconstruction once I put the plasterboards back on. But other than that, if I find them can I install the cabinets safely?

  • guyrocket@kbin.social
    link
    fedilink
    arrow-up
    15
    arrow-down
    1
    ·
    6 months ago

    In this thread: OP scaring the Americans because they think what they see in OP’s pictures is the extent of the wall.

    If fact, OP is just building out from an existing wall that is behind the OSB in his pictures.

    Grogon, ask a local carpenter. I don’t think Americans understand your German construction.

  • scrion@lemmy.world
    link
    fedilink
    arrow-up
    12
    ·
    edit-2
    6 months ago

    I’ll answer this one in German since this is my time to shine. Let me just say, the wall is perfectly fine, what we see is just another layer of OSB board for ease of installation on top of the actual wall behind it (which is well framed and insulated).

    Dies ist ein sehr unterhaltsamer thread fuer mich, da ich beide Seiten verstehen kann.

    Auf der Webseite von Wolf Haus ist die Installationsebene aus OSB zu sehen, die angegebene Punktlast ist 70kg pro Schraube. Wenn du sicherstellst, das deine Schrauben durch die Kanthoelzer in die OSB-Platte gehen, solltest du dich auf diese Angaben verlassen koennen, also eine Schraube haelt dann 70kg.

    Deutschland hat selbstverstaendlich auch eine Norm fuer Kuechenmoebel, DIN 68930. Da bekommst du ein Gefuehl dafuer, wie schwer Kuechenschraenke werden koennen. Die Nachbarn in der Schweiz verwenden die Norm SN EN 14749, zum Vergleich. Es ist nicht ungewoehnlich, einen Schrank (wall cabinet) mit 120kg Belastung zu testen.

    Beachte bitte auch die Distanz der Schrauben, man darf nicht zu nah oder zu weit setzen. Ich habe das hier auf Deutsch gefunden:

    https://www.huettemann.de/lagerkatalog/download/osb4_belastung.pdf

    Ich wuerde immer mit einem margin zur Sicherheit rechnen, vielleicht 20%. Eine Schraube haelt dann also 0.8x70kg = 56kg. Wenn du die Distanzen beachtest und dir das Gewicht deines Schrankes ausrechnest und auf entsprechend viele Schrauben verteilst, solltest du safe sein.

    Ich gehe natuerlich davon aus, das die Installationsebene von Wolf Haus fachgerecht konstruiert wurde.

    • El Barto@lemmy.world
      link
      fedilink
      arrow-up
      8
      ·
      edit-2
      6 months ago

      Aw come on! I want to learn! I just don’t want to learn German first.

      Edit: D’oh! I had missed the context. All good.

      • scrion@lemmy.world
        link
        fedilink
        arrow-up
        7
        ·
        6 months ago

        Yeah, but they made the thread and mentioned not speaking English well enough and they were really getting confused and anxious by a bunch of us claiming the only way to turn this situation around is to demolish the building - at that point, some helpful reassurance was in order.

        The gist of what I said was: the wall is fine, the manufacturer assures a point load of 70kg for the installation layer (so basically 70kg per screw), looking at some local regulations will give you an idea of how heavy a kitchen wall cabinet can get (going at it from this angle is helpful in case you need to discuss liabilities at some point), distribute that load over screws mounted at proper distances, add a safety margin and you should be good.

        • El Barto@lemmy.world
          link
          fedilink
          arrow-up
          1
          ·
          6 months ago

          Whoops! I had missed that part about struggling with English. You’re a good person. Thanks!

      • scrion@lemmy.world
        link
        fedilink
        arrow-up
        2
        ·
        6 months ago

        Noch etwas: die beste Methode ist wirklich, sich mit Bleistift vor der Montage der Gipskartonplatten die Lage der Hoelzer zu markieren.

        Falls du das an einer Stelle vergessen hast, kannst du spaeter immer noch einen stud finder verwenden. Ich kenne die amerikanischen brands, habe aber mittlerweile auch solche Geraete gebraucht und getestet.

        Der gruene stud finder von Bosch ist trash, aber der GSM120 aus der professional Reihe funktioniert gut:

        https://www.bosch-professional.com/de/de/products/gms-120-0601081000

        Findet auch elektrische Leitung und Rohre

        • Grogon@lemmy.worldOP
          link
          fedilink
          arrow-up
          1
          ·
          6 months ago

          Ja voll cool!

          Ich habe alle Wände abfotografiert und Abmessungen der Lattungen (30cm Abstände) gemerkt. Aber das es sowas gibt ist ja echt wahnsinn. Danke!

  • ikidd@lemmy.world
    link
    fedilink
    English
    arrow-up
    6
    ·
    6 months ago

    There’s about one person in this thread that knows what is going on. Ignore pretty much everyone else.

      • seathru@lemm.ee
        link
        fedilink
        English
        arrow-up
        0
        ·
        edit-2
        6 months ago

        Holy shit, is that load bearing plywood on the far wall (with the rectangle window).

        My friend, you need help from someone that knows what they are doing and familiar with local codes before proceeding any further.

        • Death_Equity@lemmy.world
          link
          fedilink
          arrow-up
          1
          ·
          6 months ago

          They are not American, Germans build way different so how they do things does not make sense without understanding what is going on.

          • Taleya@aussie.zone
            link
            fedilink
            arrow-up
            1
            ·
            5 months ago

            Not just germans, aussie here, assumed that was internal walls (which differ from external). Seen a few double brick/ concrete framed out like that

            Mind you our building standards have gone down the shitter since the 90’s…

        • Pipoca@lemmy.world
          link
          fedilink
          arrow-up
          1
          ·
          6 months ago

          That wall isn’t structural. There’s a much thicker wall behind it; this is just a thin internal layer for running electric and mounting drywall.

          • seathru@lemm.ee
            link
            fedilink
            English
            arrow-up
            0
            arrow-down
            1
            ·
            6 months ago

            https://i.imgur.com/AbsJjCh.jpeg

            My concern is that those big beams (blue) end where they meet the plywood (yellow). Which means they are transferring their downward force into the board(s) highlighted in green. That in turn presses down on the vertical studs highlighted in red. These aren’t connected to anything on the bottom. So the weight from the beams gets supported by the screws attaching all these pieces to the plywood wall? Maybe if they’re just for looks and not structural support. Maybe that’s how it’s done in germany.

            • roguetrick@kbin.social
              link
              fedilink
              arrow-up
              2
              ·
              6 months ago

              Behind the green board, behind the OSB, there is a very thick top plate that those beams are sitting on and based on what the OP said to me, that is then framed down to a sill plate also behind the OSB. Nothing on the outside of the OSB is structural and he’s actually screwing those 6x6 cm boards into what’s behind the OSB. They’re using the OSB as a vapor barrier instead of faced insulation like we do and also protecting the studs with that vapor barrier from the interior of the house.

              Edit: Truth is, what’s funny about OP’s wall and the response it’s getting is that it’s better constructed than most American buildings you could find. We don’t tend to put as big a gap between the vapor barrier and the interior heated space and we don’t tend to include the studs as protected by that vapor barrier. When we do we use plastic sheeting, not OSB, because that’s too expensive. I’d imagine the R value on his insulation is also much higher than ours.

        • Pohl@lemmy.world
          link
          fedilink
          arrow-up
          1
          arrow-down
          1
          ·
          edit-2
          6 months ago

          Yeah there is so much crazy shit going on in these pictures I am doubting my own understanding and I was a rough carpenter for several years.

          Why are the studs on the flat? Where the hell is that sill plate? No headers over the windows? No cripples under the windows? Is that stud next to the window opening cut at the bottom? Why are the studs spaced so… creatively

          I could probably spot a few more but I honestly think I just don’t know what this building is or where it is. Clearly not in US and maybe it’s a shed or something and not a dwelling. Too much I don’t know to talk shit.

          Edit: is there like an actual structural wall on the exterior that we cannot see? Maybe all this stuff is just to provide structure for drywall and electric. That would maybe make sense.

          • NegativeLookBehind@lemmy.world
            link
            fedilink
            arrow-up
            5
            ·
            edit-2
            6 months ago

            From the links he sent, it looks like he’s just building a non-structural insulating wall on the interior which allows for running electrical lines.

            • Pohl@lemmy.world
              link
              fedilink
              arrow-up
              3
              ·
              6 months ago

              I think you’re right. If this picture was taken in the US or Canada, I would be panicked for OP. But honestly I thing it might be something we don’t do here so it looks crazy, but only to us.

              • scrion@lemmy.world
                link
                fedilink
                arrow-up
                2
                ·
                6 months ago

                You’re right. After moving to Germany, I can tell there is nothing wrong with this picture, but it sure looks crazy out of context.

                Interestingly enough, most residential houses I looked at had solid, steel reinforced concrete walls everywhere.

              • roguetrick@kbin.social
                link
                fedilink
                arrow-up
                2
                ·
                6 months ago

                No, I was actually translating it for the American construction folks. What you’re doing is actually how we cover up plaster walls on remodels. It’s just not something I’ve ever dealt with when I was a construction supply salesperson.

  • themeatbridge@lemmy.world
    link
    fedilink
    arrow-up
    1
    ·
    edit-2
    6 months ago

    My advice? Knock that “wall” down and pay a proper carpenter to build a proper one. Your studs are too small, they don’t go all the way down, you have no room for insulation, and if you try to hang cabinets on that thing, you’re going to kill someone when the whole sumbitch collapses.

    My bad, I didn’t know what I was looking at. See OP’s diagram to learn more about this, and ignore my ignorance.

      • Coskii@lemmy.blahaj.zone
        link
        fedilink
        arrow-up
        1
        ·
        edit-2
        6 months ago

        That link is extremely helpful. It seems like you’re fine to attach cabinets to the wall after drywall. The osb is tied into some serious wood framing behind it, and as long as you’re using fasteners that reach into the osb, it should be about as solid as you could want.

        The kitchen metal grumpydaddy suggested isn’t expressly needed here, but that’s the most I’d consider doing to it.

    • Grogon@lemmy.worldOP
      link
      fedilink
      arrow-up
      2
      ·
      6 months ago

      Insulation is already behind the squared timber.

      The wall is actually behind the frame I am putting on the wall. It is an installation level for electricity and I can hang my plasterboards on that.

      The insulation is 240mm thick behind the Plywood. That is where the vapor barrier is and the other plywood.

      • Coreidan@lemmy.world
        link
        fedilink
        English
        arrow-up
        0
        arrow-down
        1
        ·
        6 months ago

        Unless I’m missing something I just don’t see how those studs are providing any real support to the wall.

        Empty cabinets are heavy. I’d be worried about those studs giving way.

        Hard to tell tho just looking at this picture.

  • CyLith@lemm.ee
    link
    fedilink
    arrow-up
    0
    arrow-down
    1
    ·
    edit-2
    6 months ago

    I would not. 6cm is about 2 1/2 inches and I would not rely on a wall framed any less thick than 4-by (3.5 inches). Thinner means more flexion which will lead to problems of your plaster cracking and cabinet flushness issues. In terms of strength, it’s probably okay, assuming you have fastened that framing solidly.

    The trick to finding your studs is to pre-mark your plaster board and keep transferring those marks outward up to the point of hanging your cabinets.

  • mipadaitu@lemmy.world
    link
    fedilink
    English
    arrow-up
    0
    arrow-down
    2
    ·
    6 months ago

    Are you getting this work inspected by anyone?

    That work, while precise, would not meet code where I live.